Steady-State Visual Evoked Potentials (EEG data): =================== Copyright: Hovagim Bakardjian, 2011 Email: hova@brain.riken.jp Email: hova@bakardjian.com All experiments were performed using facilities at: RIKEN, Brain Science Institute, Laboratory for Advanced Brain Signal Processing =================== EXPERIMENTAL DESIGN: EEG system: 128-channel BIOSEMI (active electrodes, see http://www.biosemi.com for cap layout) Sampling rate: 256 Hz Monitor vertical refresh rate: 170 Hz Eye-monitor distance: ~90 cm 15 seconds of SSVEP available for 4 subjects. |---------------| -----| SSVEP |----- The SSVEP ONSET point is at second 5 from beginning of the data. The SSVEP OFFSET point is at second 20 from beginning of the data. 3 SSVEP stimulation frequencies available (8 Hz, 14 Hz, 28 Hz). See corresponding text files for the precise frequencies (very small deviations). 6 trials available for each SSVEP frequency. =================== IMPORTANT NOTICES: 1. Copyright holders for this database are RIKEN-LABSP and Dr. Hovagim Bakardjian. 2. By using this data for any scientific publication, you agree to include a reference to the following original work: Bakardjian H, Tanaka T, Cichocki A, Optimization of SSVEP brain responses with application to eight-command Brain–Computer Interface, Neurosci Lett, 2010, 469(1):34-38. 3. If any part of this data is used for commercial applications, an explicit permission must be obtained from the copyright holders. Note also the following patent: Bakardjian, H., Martinez, P., Cichocki, A., Robust Multi-Command SSVEP-Based Brain-Machine Interface Without Training using Small Moving or Stationary Patterns, Japanese Patent #22385, 2008 =================== Signal processing note: The original data may contain substantial baseline shifts due to the DC properties of the Biosemi EEG system, as well as frequent eye blink artifacts for some subjects.